background image

Digital Operator 3 - 5

Drive Mode Indicators

The definition of the Drive mode indicators are shown in Table 3.2.

AUTO Sequence (SEQ) Indicator

The status of the AUTO “Sequence” (SEQ) indicator is shown in Table 3.3. This indicator is always “Off” when the Drive is in
the “Hand” mode. When the Drive is in the “Auto” mode, the SEQ indicator status is dependent on the setting of parameter
“b1-02” (Run Command Selection).

Table 3.2 Drive Mode Indicators

Indicator

Definition

FWD

Lit when a forward run command is input and when Drive is in “Hand” Mode.

REV

Lit when a reverse run command is input.

AUTO SEQ

Lit when set up for remote run command. See Table 3.3

AUTO REF

Lit when set up for remote speed command. See Table 3.4

ALARM

Lit when a fault has occurred. Flashes when an alarm has occurred.

Table 3.3 AUTO Sequence (SEQ) Indicator

Indicator Status

Hand Mode

Auto Mode

On

N/A

Parameter “b1-02” (Run Command Selection) is set to terminal strip,
communications, or an option board as indicated below:
b1-02=1 (Terminals)
=2 (Communications)
=3 (Option PCB)

Off

Parameter “b1-02” (Run Command Selection) is set to digital operator
as indicated below:
b1-02=0 (Operator)

TM_E7_01_07182008.book Page 5 Wednesday, July 23, 2008 2:35 PM