2

Installation and Start-Up

9

3/21/96

Pre-Installation Considerations

Pre-Installation

Considerations

Receipt of

Shipment

Unpacking

Re-Packing

Physical

Installation

The “Installation and Start-Up” section describes and illustrates the following:

How to select the site to install your DSD drive.

How to mount your DSD drive.

How to connect your DSD drive to incoming power and the motor .

How to start-up the system after it is installed.

The DSD drive is air cooled. The lowest HP rated units are cooled by
convection; all other units are equipped with a fan to ensure adequate air flow.
Select a site for installing the drive which is clean and well ventilated.
Maintenance will be minimized if the drive is located in a clean atmosphere. The
standard drive is designed for vertical mounting.

All equipment is fully tested at the factory. Any damage or shortages evident
when the equipment is received must be reported immediately to the commercial
carrier who transported the equipment. Assistance, if required, is available from
your MagneTek representative. Always refer to the order number, equipment
description, and serial number when contacting MagneTek.

For long periods of storage, equipment should be covered to prevent corrosion
and should be placed in a clean, dry location. If possible, equipment should be
stored in its original crating. Periodic inspection should be made to ensure that
the equipment is dry and that no condensation has accumulated. The equipment
warranty does not cover damage due to improper storage.

Remove the protective shipping material from around the equipment. Remove
all packing material. Unbolt the equipment from its crate. Inspect for loose
wiring. Make sure that all contact wedges and other shipping devices have been
removed.

The drive should be bolted in a crate which provides at least 2 inches clearance.
The drive should then be wrapped in polyethylene and covered with wax
impregnated double walled # 350 corrugation and crated. Assistance, if
required, is available from your MagneTek representative.

Attach the drive to a cabinet panel or other vertical structure using the mounting
holes provided at the back of the drive (refer to Figure 2, 3 or 3.1 for dimensions
and mounting hole locations). Allow six inches top and bottom and two inches
at sides for free air circulation. For either style, hinged door swing-out clearance
is the same as the width dimension. Ensure that the unit is level.

Storage

CAUTION

The DSD Drive Control PCB has electrostatic sensitive
components. You must follow Electrostatic Discharge (ESD)
procedures to protect the components.