3

Operation

52

3/21/96

IMPORTANT

During normal operation, and during drive power-up or -down,
the NVRAM PROTECTION switch should ALWAYS be in the
“OFF” position which prevents writes to the NVRAM.

saue

DATA

RED

Non-Volatile “RAM”-Access

Note that as soon as either the

or

key is pressed, the data indicator will

change to RED.

❏ Press the ENTER key to actually perform the transfer of data. If ENTER is

pressed while 'SAVE' is displayed, the SCDU display may change to:

This display means that the NVRAM PROTECTION switch is in the “ON”
position preventing writes to the NVRAM. Move the switch to the "OFF"
position, press the DATA/FCTN key, and start over from step #2. (See
Figure 3 in Section 3, Controls and Indicators for the location of the
NVRAM PROTECTION switch.)

During SAVE or RESTORE operation, the DATA/FCTN,

and

⇓,

ENTER

keys will not function. Functionality will resume when operation is
complete.