Fault/Error

Possible Causes &

Code

Fault/Error Name

Corrective Actions

4

Maintenance

71

Troubleshooting Guide

3/21/96

Table 3. Troubleshooting Guide – Continued

906

907

908

909

DCU Loss Fault

Thermistor Fault

Over Temperature Fault

Excessive Current Ripple Fault

1.

Too much code in the faster scans
and/or excessive DSD LAN traffic
caused the PCU to run out of scan time.

2.

DCU microprocessor failure.

Reduce the number of LAN
broadcasts or reduce the number of
directed messages to this drive.

PAC code might need to be
revised in order to optimize the
PAC execution time (contact Magnetek)

Replace main PCB. See “Replacing
Drive Control PCB”/Maintenance
Section.

Thermistor on heat sink open or shorted.

Check connections.

Check Thermistor with ohmmeter.

Replace Thermistor.

1.

Too high ambient temperature.

2.

Clogged air filter in cabinet.

3.

Clogged heat sinks.

4.

Cooling fan failure.

Check for cause of increased
ambient temperature.

Clean heat sink fins. See
“Preventive Maintenance”.

Check Cooling Fan. See “Replacing
the Fan”/Maintenance Section.

1.

a. Loose connections in power circuit.
b. Loose connections in gate leads or

from DSD Drive Control PCB to
Armature Interface PCB.

2.

a. Faulty Armature Interface PCB.
b. Faulty DSD Control PCB.

3.

Poor current or speed regulator
tuning.

Check all connections inside the power
cube.

Run self-diagnostics to check for bad
SCRs.