Maintenance, Troubleshooting guide, Table 3. troubleshooting guide – continued – Yaskawa DSD 406 User Manual

Page 69

Advertising
background image

Fault/Error

Possible Causes &

Code

Fault/Error Name

Corrective Actions

4

Maintenance

65

Troubleshooting Guide

3/21/96

Often caused by slipping nip or improper
data entry to the drive.

Regulator settings need adjusting.

Check all parameters and inputs against
application limits.

1. Thumbwheel switch connected directly

to drive contains an invalid digit

2. Selected bank of Thumbwheel switches

is not present.

Check cables and connections.

Check Bank Select jumper positions on
the Thumbwheel Selector Switch
Assemblies.

Hardware Failure in the Power Conversion
Unit

Replace main drive PCB board. See
“Replacing Drive Control PCB”/
Maintenance Section.

Hardware or Software Failure/Improper
Addressing Attempted

Unplug and reseat all cables and socketed
devices.

Replace drive main PCB board. See
“Replacing Drive Control PCB”/
Maintenance Section.

104

110

111

113

220

221

222

223

224

232

240

241

242

243

244

252

Sign Error in Speed Regulator

Bad Thumbwheel Digit

Missing Thumbwheel Switch

Missing PCU

68K ROM Bus Error

68K RAM Bus Error

68K NVRAM Bus Error

68K DPRAM Bus Error

LAN Bus Error

Unknown Bus Error

68K ROM Address Error

68K RAM Address Error

68K NVRAM Address Error

68K DPRAM Address Error

LAN Address Error

Unknown Address Error

Table 3. Troubleshooting Guide – Continued

Advertising