Maintenance, Troubleshooting guide, Table 3. troubleshooting guide – continued – Yaskawa DSD 406 User Manual

Page 69

Advertising
background image

Fault/Error

Possible Causes &

Code

Fault/Error Name

Corrective Actions

4

Maintenance

65

Troubleshooting Guide

3/21/96

Often caused by slipping nip or improper
data entry to the drive.

➊

Regulator settings need adjusting.

❷

Check all parameters and inputs against
application limits.

1. Thumbwheel switch connected directly

to drive contains an invalid digit

2. Selected bank of Thumbwheel switches

is not present.

➊

Check cables and connections.

❷

Check Bank Select jumper positions on
the Thumbwheel Selector Switch
Assemblies.

Hardware Failure in the Power Conversion
Unit

➊

Replace main drive PCB board. See
“Replacing Drive Control PCB”/
Maintenance Section.

Hardware or Software Failure/Improper
Addressing Attempted

➊

Unplug and reseat all cables and socketed
devices.

❷

Replace drive main PCB board. See
“Replacing Drive Control PCB”/
Maintenance Section.

104

110

111

113

220

221

222

223

224

232

240

241

242

243

244

252

Sign Error in Speed Regulator

Bad Thumbwheel Digit

Missing Thumbwheel Switch

●

Missing PCU

●

68K ROM Bus Error

●

68K RAM Bus Error

●

68K NVRAM Bus Error

●

68K DPRAM Bus Error

●

LAN Bus Error

●

Unknown Bus Error

●

68K ROM Address Error

●

68K RAM Address Error

●

68K NVRAM Address Error

●

68K DPRAM Address Error

●

LAN Address Error

●

Unknown Address Error

Table 3. Troubleshooting Guide – Continued