3/21/96

Fault/Error

Possible Causes &

Code

Fault/Error Name

Corrective Actions

Table 3. Troubleshooting Guide – Continued

260

261

262

263

264

265

Iteration Time-Out

Out of Sequence

Byte Time Out

Wrong File Type

Null Block Expected

User Canceled

YMODEM transfer is stopped. The drive
has tried to send or receive a character and
failed to do so within a specific timeout
period.

➊

Verify that the serial cables are attached
properly between the source PC and the
drive.

❷

Verify that the PC has the correct serial
communications settings for
communications with a drive.

YMODEM transfer is stopped. YMODEM
protocol has been violated by an out of
sequence block.

➊

Cancel and try to start over again.

YMODEM transfer is stopped.

Same corrective actions as 260.

YMODEM transfer is stopped. The drive
was sent a file whose file extension was not
recognized. The drive will accept either a
.PRG file or a .PAR file.

➊

Cancel and try again with a valid file
name.

YMODEM transfer is stopped. The
YMODEM protocol has been violated. A
null block was expected but never received.

➊

Re-initialize up load procedures on the
YMODEM software and the drive and try
again.

YMODEM transfer is stopped. A user has
aborted the file transfer from the PC.

➊

Start again if desired.