4

Maintenance

66

Troubleshooting Guide

3/21/96

Fault/Error

Possible Causes &

Code

Fault/Error Name

Corrective Actions

Table 3. Troubleshooting Guide – Continued

260

261

262

263

264

265

Iteration Time-Out

Out of Sequence

Byte Time Out

Wrong File Type

Null Block Expected

User Canceled

YMODEM transfer is stopped. The drive
has tried to send or receive a character and
failed to do so within a specific timeout
period.

Verify that the serial cables are attached
properly between the source PC and the
drive.

Verify that the PC has the correct serial
communications settings for
communications with a drive.

YMODEM transfer is stopped. YMODEM
protocol has been violated by an out of
sequence block.

Cancel and try to start over again.

YMODEM transfer is stopped.

Same corrective actions as 260.

YMODEM transfer is stopped. The drive
was sent a file whose file extension was not
recognized. The drive will accept either a
.PRG file or a .PAR file.

Cancel and try again with a valid file
name.

YMODEM transfer is stopped. The
YMODEM protocol has been violated. A
null block was expected but never received.

Re-initialize up load procedures on the
YMODEM software and the drive and try
again.

YMODEM transfer is stopped. A user has
aborted the file transfer from the PC.

Start again if desired.