Fault/Error

Possible Causes &

Code

Fault/Error Name

Corrective Actions

4

Maintenance

70

Troubleshooting Guide

3/21/96

Table 3. Troubleshooting Guide – Continued

902

(continued)

903

904

905

●

Line Sync Loss Fault

Low Line Fault

Field Loss Fault

➊

Check wiring and repair as necessary.

❷

Check boards for shorts and replace as
necessary.

❸

a. Check output of 1PT
b. Check and replace fuses as necessary.

See “Replacing Fuse(s)”/Maintenance
Section.

c. Check wiring and repair as necessary.
d. Check transformer and replace as

necessary

❹

Replace DSD Power Supply. See
“Replacing the Power Supply”/
Maintenance Section.

1. Excessively noisy or intermittent

power connections.

2. Faulty voltage dividers on Armature

Interface PCB.

3. Loss of 3 phase or 1 phase power.

➊

Check power input for problems.

❷

Replace Armature Interface PCB. See
“Replacing Armature Interface
PCB”/Maintenance Section.

1. Power line dips.

a. 1 cycle below 50%.
b. 2 cycles below 70%.
c. 3 cycles below 80%.

2. Loss of power fuse.

➊

Check input power for problems.

❷

Check for blown fuses. See “Replacing
Fuse(s)”/Maintenance Section.

1. Motor field or wiring open.

2. a. Wrong trip level set.

b. Field Economy set too low.

➊

Check motor and wiring.

❷

a. Check trip level setting.
b. Change economy setting as required.