Figure 43 linear motor track, Dmepit, Dmode – Parker Hannifin 88-021610-01G User Manual

Page 103

Advertising
background image

Parker Hannifin

Chapter 6 Command Reference 103

DMEPIT

Motor Electrical Pitch

Type

Motor (Linear only)

Product Rev

Syntax

<a_>DMEPIT<r>

Aries 1.0

Units

r = millimeters

Range

Ø to 3ШШ.ШШ : ±Ш.Ш1

Default

Ø

Response

DMEPIT: <*>4Ш.ШШ

See Also

ERES

Note:

This command does not take effect until you cycle power to the drive,

or send the

RESET

command.

The DMEPIT command sets the electrical pitch of the magnets for use with
permanent magnet brushless linear motors. The DMEPIT value is required to

convert between linear units and rotary units. The electrical pitch can be
equated to one revolution in a rotary motor. Mechanically, the definition of the
electrical pitch is the linear distance between two magnets comprising a full
magnetic cycle. For example, the illustration below shows an electrical pitch
of 42 mm (DMEPIT42).

Figure 43 Linear motor track

Important!

For rotary motors, set the DMEPIT to zero (0). The Aries drive

uses the DMEPIT parameter as the determinant for which type of motor,

linear or rotary, is connected.

DMODE

Drive Control Mode

Type

Drive Configuration

Product Rev

Syntax

<a_>DMODE<i>

Aries 1.0

Units

i = control mode setting

Range

1 to 17 (see Table 44)

Default

2

Response

DMODE: <*>2

See Also

none


Use the DMODE command to select the drive control mode for your Aries

drive. For drive mode descriptions and drive compatibility, see Table 44.

Advertising