Table 17 output power-continuous and peak, Output power, Motor connector – Parker Hannifin 88-021610-01G User Manual

Page 43

Advertising
background image

Parker Hannifin

Chapter 3 Electrical Installation 43

Output Power

Table 17 contains the continuous and peak output power ratings for all Aries
drive models.

Continuous Output

Peak Output

Drive

Current (Amps,

RMS)

Shaft Power*

(Watts, max)

Current

(Amps, RMS)

Shaft Power

(Watts, max)

AR-01xx

1.0

100

3.0

300

AR-02xx

1.75

200

5.25

600

AR-04xx

3.0

400

9.0

1200

AR-08xx

4.5

750

13.5

2250

AR-13xx

6.3

1300

14.1

3900

AR-20xE

10

2000

30

6000

AR-30xE

16

3000

48

9000

* Maximum shaft power rating at 240 VAC

Table 17 Output Power-Continuous and Peak

Motor Connector

AR-01xx, AR-02xx, AR-04xx,
AR-08xx, AR-13xx
Connector Type.......................................Removable screw terminal

Terminals ........................................6
Pitch ................... 0.200 in (5.08 mm)
Wire range .....................12-26 AWG

.......................................14-27 SWG
................................(0.12-3.30 mm

2

)

Wire strip length...... 0.310 in (8 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)

AR-20xE, AR-30xE
Connector Type.......................................Non-Removable screw terminal

Terminals ......................................10
Pitch ........................ 0.315 in (8 mm)
Wire range .....................10-22 AWG

.......................................12-23 SWG
....................................(0.5-4.0 mm

2

)

Wire strip length..... 0.25 in (6.5 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)