150 Aries User Guide

TMTEMP

Transfer Motor Temperature

Type

Transfer

Product Rev

Syntax

<a_>TMTEMP

Aries 1.0

Units

Degrees Celsius

Range

N/A

Default

N/A

Response

TMTEMP: <*>45

See Also

DMTRWC

,

DMTTCM

,

DMTTCW

,

STATUS

,

TERRLG

The TMTEMP reports the predicted temperature of the motor winding for

Parker motors. The temperature is estimated using the winding and motor
time constants, the rated continuous current, and the winding thermal
resistance. The motor will fault (and the drive reports E35–Motor Thermal
Model Fault) at an estimated winding temperature of 125°C, assuming

the ambient temperature is 40°C.

In OS 2.10, If DMTSWT equals 3, and the thermal temperature is greater than
60

°C, TMTEMP reports the higher of the motor model thermistor temperature

or the NTC thermistor temperature.

If you are using a non-Parker motor, the TMTEMP value depends on
parameters you supply for DMTRWC, DMTTCM and DMTTCW.

TOUT

Transfer Output Status

Type

Transfer

Product Rev

Syntax

<a_>TOUT

Aries 1.0

Units

N/A

Range

Ø (inactive) or 1 (active)

Default

N/A

Response

TOUT: <*>ШШШШ_ШШШШ_ШШШШ_ШШ11

See Also

none

The TOUT command returns the present status of the brake relay (bit 1) and
fault output (bit 0). Bits 2 through 15 are reserved. The return of one (1)
indicates the relevant output is active and a zero (Ø) indicates it is inactive.