S for, Dmtw, Dmttcw – Parker Hannifin 88-021610-01G User Manual

Page 117

Advertising
background image

Parker Hannifin

Chapter 6 Command Reference 117

application. Note also that the time constant of the motor winding itself
(DMTTCW) is much faster than this; therefore, the rise in winding temperature
will initially be much faster than DMTTCM would suggest.

DMTTCW

Motor Winding Time Constant

Type

Motor

Product Rev

Syntax

<a_>DMTTCW<r>

Aries 1.0

Units

r = minutes

Range

Ш.ШШ to 6Ш.ШШ : ±Ш.Ш1

Default

Ш.ШШ

Response

DMTTCW: <*>28.4Ø

See Also

DMTR

,

DMTRWC

,

DMTTCM

Auto-Setup

: When using a Parker motor and the Aries Support Tool, this

command is automatically set for the selected motor.
If you did not use the Aries Support Tool, are using non-Parker motors, or
sent an RFS command to the drive, the parameter is set to zero (0)—you

must manually set this parameter to a non-zero number.
For a list of auto-configured commands, see

DMTR

.

The DMTTCW command specifies the time constant of the motor winding

alone. This is the time for the winding to reach 63% of its final temperature
rise above the rest of the motor, given constant power. Note that this is not
the time constant usually specified in motor data sheets (see DMTTCM); the
DMTTCW value is typically much faster.

DMTW

Motor Rated Speed

Type

Motor

Product Rev

Syntax

<a_>DMTW<r>

Aries 1.0

Units

Rotary motor: r = revolutions/second
Linear motor: r = meters/second

Range

Ш.Ш to 400.Ш : ±Ш.1

Default

Ш.Ш (DMTW of Ø results in motor configuration error)

Response

DMTW: <*>15Ш.Ш

See Also

DMEPIT

,

DMTICD

,

DMTR

Auto-Setup

: When using a Parker motor and the Aries Support Tool, this

command is automatically set for the selected motor.
If you did not use the Aries Support Tool, are using non-Parker motors, or
sent an RFS command to the drive, the parameter is set to zero (0)—you

must manually set this parameter to a non-zero number. Otherwise, the drive
reports the configuration errors EØ–Motor Configuration Warning and
E4–Rated Speed = Ø, and shuts down the drive.
For a list of automatically configured commands, see

DMTR

.

The DMTW command specifies the rated speed of the motor. This is the lesser

of the following:

• (Rotary motor) Motor mechanical limited speed

Advertising