Figure 28 ar-20xe & ar30xe control, Connector, Ar-20xe & ar30xe control connector – Parker Hannifin 88-021610-01G User Manual

Page 61

Advertising
background image

Parker Hannifin

Chapter 3 Electrical Installation 61

AR-20xE & AR30xE Control Connector

On the AR-20xE & AR 30xE models, the Control connector serves for three
connections: an external power dump resistor (E

XTERNAL

R

EGEN

), a control

power circuit (C

ONTROL

I

NPUT

P

OWER

), and a safety brake relay (B

RAKE

R

ELAY

). The connector is an eight-position non-removable screw terminal.

Specifications for the connector follow in this section.

The Control connector has a factory-installed link between R

INT

and R

− for an

internal regeneration resistor, which provides thermal protection. For more
information, see “Regeneration Protection” on page

54

. For information on

additional connections, see “Control Power Supply” on page

46

and “Brake

Relay (Optional)” on page

50

.

Figure 28 AR-20xE & AR30xE Control

Connector


AR-20xE, AR-30xE

................................ PCD: ELM021100

Parker Hannifin Part Number.................. N/A (not replaceable)

Connector Type.......................................Non-Removable screw terminal

Terminals ........................................8
Pitch ...................... 0.400 in (10 mm)
Wire Range ....................12-28 AWG

.......................................14-29 SWG
................................(0.12-3.30 mm

2

)

Wire Strip length 0.250 in (6.35 mm)