Trev, Tsspd – Parker Hannifin 88-021610-01G User Manual

Page 152

Advertising
background image

Parker Hannifin

152 Aries User Guide

the feedback device. TPER does not apply in DMODE2 (torque/force control
mode) and in DMODE4 (velocity control mode); TPER reports zero in these

modes.

TREV

Transfer Revision Level

Type

Transfer

Product Rev

Syntax

<a_>TREV

Aries 1.0

Units

N/A

Range

N/A

Default

N/A

Response

TREV:

<*>Aries OS Revision 1.Ø

See Also

RESET

,

RFS

,

STATUS

The Transfer Revision Level (TREV) command reports the software revision

of the Aries firmware.

The Aries Resolver option reflects the Resolver feedback capability by
stating ‘Aries Resolver’ in the software revision reportback instead of ‘Aries’.

Updating the drive’s operating system

: The operating system file is

located in the “Support & Downloads” section on the Parker Hannifin Motion
Online

website (

www.parkermotion.com

).

TSSPD

Transfer PWM Update Period

Type

Transfer

Product Rev

Syntax

<a_>TSSPD

Aries 1.0

Units

Microseconds

Range

N/A

Default

N/A

Response

TSSPD: <*>62.5Ø

See Also

DPWM

The TSSPD command reports the current PWM update period in

microseconds. This is not the current loop update rate, which is fixed at 62.5
μs.

Advertising