Parker Hannifin

Chapter 6 Command Reference 109

If the DMTIP value exceeds the drive’s maximum output current (TDIMAX),
the DMTIP value will be ignored and the maximum allowable value will be
used (see Table 45). The drive reports EØ–Motor Configuration
Warning and E12–Peak Current Too High.

Maximum Current Rating (RMS)

AR-01xx

3A

AR-02xx

5.25A

AR-04xx

9A

AR-08xx

13.5A

AR-13xx

14.1

AR-20xE

30

AR-30xE

48

Table 45 Peak Current Rating for Aries Drives

DMTJ

Motor Rotor Inertia / Forcer Mass

Type

Motor

Product Rev

Syntax

<a_><!>DMTJ<r> (does not take effect until RESET or
cycle power)

Aries 2.0

Units

Rotary motor: r = kgm2 * 1Ø-6
Linear motor: r = kg

Range

Rotary motor: Ш.ШШШ to 1ШШШШШШ.ШШШ : ±Ш.ШШ1
Linear motor: DMEPIT (electrical pitch) dependent

Default

Ш.ШШШ (DMTJ of Ø results in motor config. error)

Response

DMTJ: *DMTJ2ШШ.6ШШ

See Also

DMTR

,

CONFIG

Note:

This command does not take effect until you cycle power to the drive,

or send the

RESET

command.

Auto-Setup

: When using a Parker motor and the Aries Support Tool, this

command is automatically set for the selected motor.
If you did not use the Aries Support Tool, are using non-Parker motors, or
sent an RFS command to the drive, the parameter is set to zero (0)—you

must manually set this parameter to a non-zero number.
If the drive is powered up when this command is set to zero (for instance, if
RFS is executed), the drive reports a motor configuration error with E13, and
shuts down the drive (DRIVEØ).
For a list of auto-configured commands, see

DMTR

.

The DMTJ command sets the motor rotor inertia for rotary motors, or the

forcer mass for linear motors.