Resetting the fault

After the internal temperature has dropped below the values shown in Table
54, you can
clear the latched fault. There are two methods available:

Cycle power to the Aries drive.

–or–

► Open the Aries Support Tool. Then select Operating System Update

from the menu and click Reset Drive.

Model

Reset Temperature

AR-01xx, AR-02xx, AR-04xx,
AR-08xx, and AR-13xx

75°C (167°F)

AR-20xE and AR-30xE

85°C (185°F)

Table 54 Reset Temperature Values

Under-Voltage Protection

The Aries drive’s under voltage protection circuit monitors AC input voltage. If
the voltage falls below a specific value while the drive is operating, the drive
issues an under-voltage fault and turns off power to the motor output
terminals (

MOTOR

connector). This allows the motor to freewheel to a stop.

Threshold Voltage
AR-01xx, AR-02xx, AR-04xx,
AR-08xx, and AR-13xx ........................... Voltage below 70 VAC trips fault

AR-20xE and AR-30xE ........................... Voltage below 160 VAC trips fault

Results of Fault ....................................... Power to motor is turned off

Fault output is activated

LED Left

LED Right

Yellow

Red

Table

55

LED

Under-Voltage

Fault

Resetting the fault

To clear the latched fault, choose one of the following methods:

Cycle power to the Aries drive.

–or–

► Open the Aries Support Tool. Then select Operating System Update

from the menu and click Reset Drive.

Warning —

When an under-voltage protection fault occurs, the drive

disables power to its motor output terminals on the Motor connector. This
cuts all control to the motor and allows the load to freewheel to a stop.