Table 60 control power filter selection, Table 61 mains motor power filter selection, Control power – Parker Hannifin 88-021610-01G User Manual

Page 194: Mains motor power

Advertising
background image

Parker Hannifin

194 Aries User Guide

remove the paint in certain areas to ensure filters and drive make a
good large-area metal to metal contact between filter case and
panel.

You must install a filter on both the Motor power mains and Control
power mains if both are used. Use Table 60 and Table 61 to determine
the correct filter for your specific application.

Control Power

Control power is 1 Amp, maximum. Any of the following filters works with all
models of the drive.

Filter

Manufacturer

6EP1 (160937-5)

Corcom

10EP1 (160937-7)

1,

Corcom

FN2070-10/06

Schaffner

1. Available from Parker:

10 Amp filter—part number 47-016140-01

16 Amp filter—part number 47-017900-01

Table 60 Control Power Filter Selection

Mains Motor Power

Filter

Continuous
Current
(Amps)

AR-
01xx

AR-
02xx

AR-
04xx

AR-
08xx

AR-
13xx

AR-
20xE

AR-
30xE

6EP1 (160937-5)

1

5 at 240 VAC

Ч

Ч

10EP1 (160937-7)

1, 3

8 at 240 VAC

Ч

Ч

Ч

Ч

x

FN2070-10/06

2

10 at 240 VAC

Ч

Ч

Ч

Ч

x

FN2070-12/06

12 at 240 VAC

Ч

Ч

Ч

Ч

x

FN2070-16/06

2, 3

16 at 240 VAC

Ч

Ч

x

16FCD10

1

16 at 240 VAC

x

25FCD10

1

25 at 240 VAC

x

x

Product with applicable mains filter denoted by “

×”

1. Corcom (a division of Tyco Electronics)
2. Schaffner
3. Available from Parker:

10 Amp filter—part number 47-016140-01

16 Amp filter—part number 47-017900-01

Table 61 Mains Motor Power Filter Selection

• Install Transient suppressors.

Single Phase Input
You must install varistors or other voltage surge limiting devices in order
to meet the requirements of EN61000-4-5. Place a Littelfuse
V275LA2ØC, or an equivalent varistor, from line to line and from lines to
earth before the mains filter, as shown in the EMC Installation drawings.
(Intersil, General Electric, and Littelfuse manufacture equivalent
varistors.)

Advertising