Parker Hannifin

Chapter 6 Command Reference 133

FLTDSB

Fault on Drive Disable

Type

Drive Configuration

Product Rev

Syntax

<a_>FLTDSB<b>

Aries 1.0

Units

b = enable bit

Range

Ø (disable) or 1 (enable)

Default

Response

See Also

ERROR

,

FLTSTP

,

TOUT

Use the FLTDSB command to enable/disable the Fault on Drive Disable
mode. If Fault on Drive Disable is enabled (FLTDSB1 – default setting), and

the drive is disabled via the Enable input, fault output is activated and the
brake relay is opened.

FLTSTP

Fault on Excessive Startup Voltage

Type

Drive Configuration

Product Rev

Syntax

<a_>FLTSTP<r>

Aries 1.0

Units

Volts

Range

Ø to 1ØV

Default

1ØV

Response

FLTSTP: <*>1

See Also

DMODE

Use the FLTSTP command to set the threshold for the Fault on excessive

startup voltage. The default is 10.00V, so no command input will fault the
drive. If the threshold is set lower, a command voltage above this level, when
the drive is enabled, will fault the drive. To re-enable the drive without
causing a fault, command an input voltage below the set value.

IANI

Invert Analog Input

Type

Drive configuration

Product Rev

Syntax

<a_>IANI<b>

Aries 2.10

Units

b = enable bit

Range

0 (do-not invert analog input) or 1 (invert analog
input)

Default

0

Response

IANI <*>0

See Also

ENCPOL

,

CMDDIR

,

DCMDZ

,

TANI

Note:

This command requires a reset to take effect

The IANI command inverts the polarity of the analog input to the drive. This

has the effect of reversing any torque or velocity command. It can be useful
when using custom wiring during initial setup of the drive.