Dmvlim – Parker Hannifin 88-021610-01G User Manual

Page 118

Advertising
background image

Parker Hannifin

118 Aries User Guide

• (Rotary motor) Encoder limit of 5 MHz (pre-quadrature)
• Linear motor speed limitations include encoder resolution and track

length.

• The corner of the continuous speed/torque or speed/force curve

(the point where the continuous and peak torque/force curves
meet).

The DMTW value is used in conjunction with DMTICD to protect the motor from

thermal damage.

DMVLIM

Velocity Limit

Type

System

Product Rev

Syntax

<a_>DMVLIM<r>

Aries 1.0

Units

Rotary motor: r = revolutions/second
Linear motor: r = meters/second

Range

Ш.ШШ to 40Ш.ШШ : ±Ш.Ш1

Default

125.ØØ

Response

DMVLIM: <*>5Ш.ШШ

See Also

DMODE

,

DMTR

Auto-Setup

: When using a Parker motor and the Aries Support Tool, this

command is automatically set for the selected motor.
If you did not use the Aries Support Tool, are using non-Parker motors, or
sent an RFS command to the drive, the parameter is set to zero (0)—you

must manually set this parameter to a non-zero number.
For a list of auto-configured commands, see

DMTR

.

The DMVLIM command sets a limit that the commanded velocity cannot

exceed without affecting gains or scaling. This is typically used to protect
parts of the mechanical system.

If the velocity demand from the internal Aries control loops exceeds the limits
set by DMVLIM, the Aries invokes the “Override Mode”, in which the drive
software clamps the maximum velocity to the value set by DMVLIM.