Control power supply – Parker Hannifin 88-021610-01G User Manual

Page 46

Advertising
background image

Parker Hannifin

46 Aries User Guide

Control Power Supply

With Mains power applied to the Control power terminals C1 and C2, the
drive’s internal control board remains powered when the primary motor AC
power source (L1, L2 (L3)) is disconnected. When operated in this
configuration, the Control power input performs a “keep-alive” function. The
keep-alive circuit maintains several important functions, including
communications, diagnostics, position feedback, and other logic functions,
while removing power from the motor output connection. (See the following
section, Fuse Information, for a complete list of Control power functions.)

Remove the factory installed jumpers to use the product with separate
control and motor mains AC power input.

Fuse Information

Fuse Rating............................................. 1 Amp

Fuse Type ............................................... Class CC (Bussmann KTK-R-1 or

equivalent UL listed fuse)

Input Voltage Range ............................... 120/240 VAC, 50/60 Hz

Input Current ...........................................0.2 Amps RMS

Control Power Functions......................... Communications

Diagnostics
Motor position feedback
Fault output in fault mode
Brake relay in brake mode
Reset input

Control Power Connector

AR-01xx, AR-02xx,
AR-04xx, AR-08xx, AR-13xx
Connector Type....................................... Removable screw terminal

Terminals ........................................7
Pitch ................... 0.200 in (5.08 mm)
Wire Range ....................12-26 AWG

.......................................14-27 SWG
................................(0.12-3.30 mm

2

)

Wire Strip length .. 0.31 in (7.87 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)

Advertising