Revision d changes, Revision c changes – Parker Hannifin 88-021610-01G User Manual

Page 14

Advertising
background image

Parker Hannifin

14 Aries User Guide

Revision D Changes

This document, 88-021610-01D, supersedes 88-021610-1C. Changes
associated with Aries User Guide revisions, and document clarifications and
corrections are as follows:

Topic Description
Regulatory Compliance Aries is no longer cUL compliant.
Output Power

Corrected to 14.07A

Part Number

In Appendix C, Table 62 Enclosure Mounting
Clamps
, corrected part number to read R CLAMP
KIT.

Environment and Drive
Cooling

Removed separate Still Air and Moving Air
temperature maximums. Now provides only an
Ambient Air temperature.

Revision C Changes

This document, 88-021610-01C, supersedes 88-021610-1B. Changes
associated with Aries User Guide revisions, and document clarifications and
corrections are as follows:

Topic Description
Models

Enhancement: Added models AR-13xx, AR-20xE,
and AR-30xE, and relevant information.

Regeneration
Protection

Enhancement: Added discussion and connections.

DC Inductance Link

Enhancement: Added discussion and connections.

Command Reference

Enhancements: Added the following commands:
ALIGN , DMTSWT, DRES, ENCOFF, ESTORT, IANI,
OHALL, P163
Modified the following commands:
DMTTCM—range
DMTTCW—range
DVMLIM—range and default
DPWM—range and corrected mode information
ERROR—now includes messages E47 and E48

SFB—In OS 2.10 or higher, SFB also functions to
set feedback type
TMTEMP—Added new reporting capabilities for
OS 2.10 or higher

Error Messages

Enhancement: Added error messages E47 and
E48. See Chapter 7 Troubleshooting.

Advertising