Chapter 3 Electrical Installation 47

AR-20xE, AR-30xE

Connector Type.......................................Non-Removable screw terminal

Terminals ........................................8
Pitch ...................... 0.400 in (10 mm)
Wire Range ....................12-28 AWG

.......................................14-29 SWG
................................(0.12-3.30 mm

2

)

Wire Strip length 0.250 in (6.35 mm)

Control Power Connection

Figure 19 shows how to connect the Control power source to the drive. Use
the screw terminal connector that is supplied with the drive.

Figure 19 Mains Control Input Power

Warning

— You must connect the drive’s protective conductor terminal,

marked with the earth symbol

, to a reliable system Protective Earth.

Warning

— The drive’s connector strip terminals have hazardous

voltages when power is applied to the drive, and up to several minutes
after power is removed. Lower voltages may still be present for several
minutes after power is removed. During normal operation, these high
voltage terminals must not be accessible to the user.