Table 9 ar-30xe power dissipation, Cabinet cooling calculations, Ep p − ∗ = 1 – Parker Hannifin 88-021610-01G User Manual

Page 27

Advertising
background image

Parker Hannifin

Chapter 2 Mechanical Installation 27

Figure 4 Cabinet losses for AR-30xE when connected to a Parker MPM1422CSJ motor

Shaft Power

Voltage

0W*

1500W

3000W

240 VAC

35W

103W

172W

* Drive enabled, zero torque.

Table 9 AR-30xE Power Dissipation

Cabinet Cooling Calculations

Use the motor’s speed torque curve to determine the torque when the motor
is at running speed for your application. If the torque is not known, use the
“knee” (where the peak-torque curve intersects the continuous-torque curve)
of the graphed motion—this assumes the worst-case scenario for continuous
motion.

(

)

DRIVE

MOTOR

MOTOR

LOSS

E

E

P

P

=

1

P

LOSS

=

power dissipated to cabinet (Watts)

P

MOTOR

=

shaft power of the motor (Watts)

E

MOTOR

=

efficiency of motor (Percent), approximately 0.85

E

DRIVE

=

efficiency of Aries drive (Percent), approximately 0.90

Advertising