34. Maintaining The Router

Revision 1.14.3

285

RX1000/RX1100™

The Sample Interval configures how often should the system run configured shell command to get
a sample.

The Command configures the shell command to run.

The Comparator configures how to compare with the shell command result.

The Threshold configures the threshold to compare with the shell command result to see whether
the condition is true or false.

The And Repeats configures how many times the condition must be true before the alert is generated.

The And Until configures how many seconds the condition should be true before an alert is generated.

The Not Cleared Repeats configures how many times the condition must be false before the alert
is cleared.

The Not cleared Until configures how many seconds the condition must be false before an alert is
cleared.

The Parameters for RMON table allows user to configure additional parameters if the alert definition
entry type is RMON type.

The Device Name configures the name of the device to be monitored.

The MIB Variable configures the MIB variable being monitored.

The Sample Interval configures how often samples should be generated.

The Rising Threshold configures the value that will trigger an event when the value of the variable
increments past this value.

The Falling Threshold configures the value that will trigger an event when the value of the variable
decreases past this value.

The Startup configures the condition that will cause the initial event.

34.3. Industrial Defender

RX1100 owners can use the Industrial Defender security appliance for central monitoring. The central
monitoring facility is called a Security Event Management (SEM) unit. This section details how to
activate the Industrial Defender Agent on a RuggedRouter so that it can periodically report to an
SEM unit. Details and recommendations on using the Industrial Defender system can be found in the
Industrial Defender documentation.

34.3.1. What information is sent to an SEM unit

The Industrial Defender Agent will currently forward the following information to an SEM unit on a
periodic basis: