Optibase MGW 2400 WMT User Manual

Page 93

Advertising
background image

Chapter 3

• Editing Channel Parameters

Parameters Settings

Comments

Video Buffer
Window

1000 (default)

Latency related
parameter.
We recommend not
changing this parameter.

Dup Top Lines 0 - 10 (default is 0)

Sets the number of lines
'covered' on the top of
the frame to prevent the
display of artifacts.

Dup Bottom
Lines

0 - 10 (default is 1)

Sets the number of lines
'covered' from the bottom
of the frame to prevent
the display of artifacts.

DCT Filter

Automatic (default)
Disabled
Level 1
Level 2

Removes details to
smooth blocking effects
at low bit-rates.

Smooth Filter

Automatic (default)
Disabled
Level 1
Level 2

Smoothes blocking
effects at low bit-rates.

Intra Period

2 - 240
Auto (default)

Specifies the distance
between referenced I
frames in the stream. To
automatically specify the
distance, check the
checkbox next to the
Intra Period field.

Table 28: Advanced Video Encoding Parameters

83