Program steps, Operation manual – ACU-RITE MILLPWR 3 Axes User Manual

Page 155

Advertising
background image

PROGRAM STEPS

MILLPWR

®

Operation Manual

5-59

Press the

AUXILIARY FUNCTION

softkey.

Highlight the auxiliary relay(s) that you want to program. (For example, “AUX 1”
refers to the output device that’s connected to pins 1 and 2 on the J18 connection.)
Select from the

OFF

,

ON

and

PULSED

softkeys for the relay(s).

ON:

When the Auxiliary Function Step is executed, an output signal is
generated. The signal will continue until another Auxiliary Function
Step programmed to turn the signal OFF is executed , the

TABLE STOP

button is pressed, an E-Stop input signal is detected, the program is
stopped, or the program ends.

OFF:

When the Auxiliary Function Step is executed, any current signal is
turned off.

Pulsed:

When the Auxiliary Function Step is executed, an output signal is gener-
ated for the time duration specified. The signal will continue until the
time duration ends, another Auxiliary Function Step programmed to turn
the signal OFF is executed, the

TABLE STOP

button is pressed, an E-Stop

input signal is detected, the program is stopped, or the program ends.

If you selected "Pulsed," then enter the amount of time (in seconds) that you want
the relay to remain on. The maximum amount of time that a relay can pulse is 999.9
seconds.

Highlight the Display User Prompt field.

NO:

If you do not want an operator prompt to be displayed press

NO

.

Before Step:

Pressing Before Step causes an operator prompt to display before the
auxiliary function(s) execute. The prompt will show you what each out
put will do. Pressing

GO

will execute the auxiliary function(s).

After Step:

Pressing After Step causes the operator prompt to display after the
auxiliary function(s) execute. The program will pause until

GO

is pressed

or a signal from an auxiliary device is received.

Pressing “Yes” for the Set Continuous field allows an Auxiliary Function Step to be entered
(e.g. activate coolant) without interrupting the continuous milling path.

Press the

USE

key.

Note:

Check that the devices you are using are powered on before running
your program.

Advertising