ACU-RITE MILLPWR 3 Axes User Manual

Page 33

Advertising
background image

DRO

MILLPWR

®

Operation Manual

2-10

Position the tool so that it is near, but not touching,
the left side of the part.

Lower the tip of the tool so that it falls below
the top surface of the part.

Slowly move the table along the X-axis, spinning
the tool by hand as you go. Pay close attention as
the tool approaches the part—you'll feel a subtle
bump when they come into contact. Stop the table at the moment the tool touches
the part.

Using the keypad, enter the radius of the tool (the distance from the
center of the tool to the edge of your part). Be sure to specify if it’s
a negative value.

Note: In this example, a negative value will need to be specified

because the tool's center is on the negative side of the datum
(refer to Axis Conventions located in Section 1).

Press the

ENTER

key.

Now set datum for the Y-axis using the same procedure:

Position the tool so that it is near, but not touching,
the front face of the part. The tip of the tool should
fall below the top surface of the part.

Slowly move the table along the Y-axis, spinning the
tool by hand as you go. Pay close attention as the tool
approaches the part—you'll feel a subtle bump when they make contact with
each other. Stop the table at the moment the tool touches the part.

Using the keypad, enter the radius of the tool into the"Y" field
(be sure to specify if it is a negative value).

Press the

ENTER

key.

Use the MOVE
TABLE softkey
to help with
long table
moves.

Advertising