SETUP

MILLPWR

®

Operation Manual

7-28

AMI Outputs

In Position Relay

The Auxiliary Machine Interface (AMI) has the ability to send a signal to external devices. This signal
is sent when

MILLPWR

is in position for Position Drill steps and Hole pattern steps. This is when the

table has moved to either the X, Y coordinates of the position drill step or to each hole of a hole pat-
tern.

Choose the appropriate signal for your application from the three options explained below.

ON:

When the X, Y coordinates for the position drill step or when each hole of a
hole pattern is reached, a signal is sent for output. This signal will continue to
be output until the

GO

button is pressed, a GO signal is received through the

AMI, the table stop is activated, the program is stopped, or the program ends.

OFF: No signal is sent.

Pulsed: With this option the signals will only be sent for the timed intervals that you

establish. Enter a time interval between 0.1 and 999.9 seconds. When the X, Y
coordinates for the position drill step, or when each hole of a hole pattern is
reached, a pulsed signal will be sent. This signal will continue until either the
pulse time interval expires, the

GO

button is pressed, a GO signal is received

through the AMI, the table stop button is activated, an E-Stop input is detected,
the program is stopped or the program ends.