Operation manual – ACU-RITE MILLPWR 3 Axes User Manual

Page 31

Advertising
background image

DRO

MILLPWR

®

Operation Manual

2-8

To skew a part or vise:

Using an electronic edge finder

Press the

SKEW

softkey.

Touch off on two or more points along any single straight edge
of your part. You’ll notice the “Points” and “Angle” change as
you enter points.

MILLPWR

will calculate the angle to the

closest axis line and compensate for the offset of the workpiece.

Press the

USE

key to accept all of the points and return to the

DRO screen. Press the

CANCEL

key to return to the DRO screen

without accepting any points or affecting your previous skew
angle.

The

CLEAR ANGLE

softkey will reset the number of points and the skew angle

to zero.

Using teach position:

Press the

SKEW

softkey.

Move the table so that a mechanical indicator rests against any straight edge
on the part. Press the

TEACH POSITION

softkey to enter your coordinate.

You’ll notice that the “Points” change.

Now move the table so that the mechanical indicator touches another point on
the same straight edge. Press the

TEACH POSITION

softkey. You’ll notice that the

“Points” and “Angle” change.

Repeat this process for any additional points.

MILLPWR

will calculate the angle

to the closest axis line and compensate for the offset of the workpiece.

Press the

USE

key to accept all of the points and return to the DRO screen.

Press the

CANCEL

key to return to the previous screen without affecting your

previous skew angle.

The

CLEAR ANGLE

softkey will reset the number of points and the angle to zero.

Here we used
a workpiece as
an example.
You can also
“touch off” on
a vise or fix-
ture.

Advertising