ACU-RITE MILLPWR 3 Axes User Manual

Page 34

Advertising
background image

DRO

MILLPWR

®

Operation Manual

2-11

Setting datum for the Z-axis:

Position the tool so that its tip touches the top surface
of the part.

Using the keypad, enter "0" into the "Z" field
(or press the Z = 0 softkey).

Press the

ENTER

key.

Highlight the “Z Retract” field.

Either:

Enter the Z-axis retract position (the position that you want the quill to return to
between steps—it must be located above the top surface of the part); OR

Raise the quill to the desired retract position, then press the

TEACH

softkey.

Press the

USE

key.

Datum and the Z-axis retract position have now been established.

It's a good idea to test the datum setting
before beginning programming. To confirm
that the new datum is correct:

• Raise the tool and move the table until

both the X- and Y-axes displays read
"0.0000."

• Lower the tool until it touches the part.

• Check the tool's position. The lower left

corner of the part should be located

directly beneath the center point of the tool.

• Now check the readout. If the Z-axis display says "0.0000," then the

datum is accurate and programming can begin. If a value other than
0.0000 appears in the Z-axis display, repeat the procedure for establishing
datum.

You can quickly
move to Datum
for X and Y by
pressing the
POS key. Check
that your posi-
tion is 0.0000
ABS for both X
and Y, then
press the GO
key.