Troubleshooting guide – ACU-RITE MILLPWR 3 Axes User Manual

Page 229

Advertising
background image

TROUBLESHOOTING GUIDE

MILLPWR

®

Operation Manual

9-4

Operator console keypad
does not function properly.

Power down the system. Wait
for approximately one minute
then power the system up.
Remember to reestablish
machine tool zero using the
"Find Home" routine.

Run the Keypad Test (refer to
Diagnostics, Section 7).

Should the above recommenda-
tion not correct the problem you
are experiencing, contact your
ACU-RITE distributor for
repair and/or replacement pro-
cedures.

System needs to be reset.

Symptom

Recommended
Corrective Action

Probable Cause

System powers up, but
motor(s) will not move.

MANUAL POSITIONING

selected in "Run Options."

GRAPHICS ONLY

selected in

"Run Options."

Table stop button has been
pressed.

Check the message bar for the
following message: “Table Stop
Button is Pressed.”

Release the table stop button
and press the

CLEAR

key.

Review selections in "Run
Options.”

Review selections in "Run
Options.”

Check the message bar for the
following message: “DSP fault-
(X,Y, or Z) axis position error
check failed.”

Improper Scale Connection

Advertising