PROGRAMMING

MILLPWR

®

Operation Manual

3-9

Using an electronic edge finder:

From the DRO screen, press the

SKEW

softkey.

Touch off on two or more points along any single straight edge of your part. You’ll
notice that the “Points” and “Angle” change as you enter points.

Press

USE

to accept all of the points and return to the DRO screen. Press

CANCEL

to

return to the DRO screen without accepting any points or affecting your previous
skew angle.

The

CLEAR ANGLE

softkey will reset the number of points and the skew angle to zero.

Using teach position:

From the DRO screen, press the

SKEW

softkey.

Move the table so that a mechanical indicator rests against any straight edge on the
part. Press the

TEACH POSITION

softkey to enter your coordinate.You’ll notice that the

“Points” change.

Now move the table so that the mechanical indicator touches another point on the same
straight edge. Press the

TEACH POSITION

softkey. You’ll notice that the “Points” and

“Angle” change.

Repeat this process for any additional points.

Press

USE

to accept all of the points and return to the DRO screen. Press

CANCEL

to

return to the previous screen without affecting your previous skew angle.

The

CLEAR ANGLE

softkey will reset the number of points and the angle to zero.