Programming, Operation manual – ACU-RITE MILLPWR 3 Axes User Manual

Page 68

Advertising
background image

PROGRAMMING

MILLPWR

®

Operation Manual

3-32

Starting and Stopping a G-code Program
Always start the program from a place in the program where the feed rate, X-, Y-, and Z-
axis position are known, such as a tool step. Alternate starting points can be programmed
by placing the proper code in the desired locations.

Pressing the

GO

button will cause

MILLPWR

to begin executing the current G-code program.

Always insure the program step highlighted is an appropriate starting point.

When a program is running, pressing the

STOP

button or the remote pendant will cause the

program and all axis motion to pause. Pressing the remote pendant switch again or the

GO

button will cause the program to resume. Pressing the

STOP

button a second time will halt

the program execution.

Advertising