Troubleshooting guide – ACU-RITE MILLPWR 3 Axes User Manual

Page 238

Advertising
background image

TROUBLESHOOTING GUIDE

MILLPWR

®

Operation Manual

9-13

Poor dimensional accuracy
(cont’d)

The quick release knob for
the Z-axis drive is loose.

Tighten the quick release
knob.

Should the above recommen-
dations not correct the prob-
lem you are experiencing,
contact your ACU-RITE dis-
tributor for repair and/or
replacement procedures.

BAUD rate error

MILLPWR

and PC BAUD

rate settings do not
match.

Change one of the settings
so that the BAUD rates for

MILLPWR

and your PC are

the same.

Check sum error

MILLPWR

and PC BAUD

rate settings do not
match.

Change one of the settings
so that the BAUD rates for

MILLPWR

and your PC are

the same.

BAUD rate is too slow or
too fast.

Adjust the BAUD rates on
both

MILLPWR

and your

PC. Check that they match
when you’re finished
adjusting them.

No response from PC

Incorrect serial cable

Verify that you are using
the correct type of serial
cable. Refer to page 8-1,
choosing a serial cable

MILLPWR

and PC BAUD

rate settings do not match

Change one of the settings
so that the BAUD rates for

MILLPWR

and your PC are

the same.

Symptom

Recommended
Corrective Action

Probable Cause