SETUP

MILLPWR

®

Operation Manual

7-27

13. The control will cause the axis to begin moving back and forth approxi-

mately two (2) inches in each direction.

14. While the axis is moving, the control automatically adjusts the Gain value until

the “Following Error” is at its lowest value.

15. Once the control has reach the optimal Gain value, it will automatically stop

axis motion and indicate it is done by displaying “Test Completed.”

16. The correct values for the Gain and Balance tests have now been established.

Now you will need to exit and save the new values in to the console.

17. Press the

STOP TEST

soft key, then press the

USE NEW SETTINGS

soft key.

18. Power down the console and restart to begin normal operation and have the

updated values implemented.