TROUBLESHOOTING GUIDE

MILLPWR

®

Operation Manual

9-6

System powers up but
motor(s) will not move.
(cont’d)

Improper X- and/or Y-axes
servo connection.

Symptom

Recommended
Corrective Action

Probable Cause

The scale(s) miscount in
certain areas only

Re-install the scale(s) and
realign the reading head(s).

Do not attempt to remove the
Z-axis scale. Contact your
ACU-RITE distributor for
repair and/or replacement.

Should the above recommenda-
tion not correct the problem
you are experiencing, contact
your ACU-RITE distributor for
repair and/or replacement pro-
cedures.

Motors are not receiving
power

Message bar reads: “

(X, Y,

OR

Z)

SERVO UNPLUGGED FAULT

.

” Check

the X-, Y- and Z-axes servo
connections located on the rear
of the Operator Console.

Check that the power connec-
tions for each motor assembly
and that the Servo Power con-
nector (located on the rear of
the operator console) are prop-
erly seated.

Enable the Motor Monitor
(refer to Diagnostics, Section 7).

For Z-axis Optional Linear
encoder:

Remove the X- or Y-axis
scale(s). Clean the glass
(located inside the aluminum
extrusion) and the reading head
glass using a cotton swab and
denatured alcohol or acetone.