Setup, Operation manual – ACU-RITE MILLPWR 3 Axes User Manual

Page 212

Advertising
background image

SETUP

MILLPWR

®

Operation Manual

7-32

The table stop test shows whether or not an emergency stop (E-stop) condition has been
detected or the internal switch has been pressed.

Table Stop Test

Reports on whether or not the system detects an emergency stop
condition. An E-stop condition can originate from the operator
console, Z-axis, or optional AMI.

Displays the status of the table stop button (Pressed or Released)
on the operator console.

E-stop Signal

Status

Table Stop

Button

To display the table stop test:

From the Diagnostics screen, highlight "Table
Stop Test" and press

ENTER

. The test will run

automatically.

When the test is complete, press the

EXIT TEST

softkey to close the “Table Stop Test” screen.

Continue with Diagnostics or press the

USE NEW

SETTINGS

softkey.

Z-Limit

If Z-axis control is enabled, a “Fault” or “No Fault” message will
appear. A fault indicates that at least one of the limit switches on
the spindle has been disengaged.

Advertising