Setup, Operation manual – ACU-RITE MILLPWR 3 Axes User Manual

Page 193

Advertising
background image

SETUP

MILLPWR

®

Operation Manual

7-13

FROM POINT

allows you to determine whether your “From” point will appear as an absolute

value or an incremental value. Absolute values are based upon the distance from datum.
Incremental values are based upon the distance from one feature or step in a program to
another. No matter which you choose as your default setting, the other will always be avail-
able by pressing the

ABS/INCR

key.

Absolute “From” points will appear like this:

MILL LINE

002

From
X1

4.0050 ABS

Y1

2.5025 ABS

Incremental “From” points will appear like this:

MILL LINE

003

From
X1

0.0000 INC

002

Y1

0.0000 INC

002

STEPOVER ENTRY

enables you to define how much material your tool will remove as it cuts a

pocket, slot or ring. To enter a value as a decimal, press the

DECIMAL

softkey. To enter a value

using whole numbers, press the

PERCENTAGE

softkey.

PASS/PECK/RETRACT

establishes the units that are applied to the “Pass,” “Peck” and “Tool

Retract” features during programming.

“Pass” refers to the number of cuts that are used to machine an area to its “End” depth.
“Peck” lets you break chips and reduce chip buildup during drilling operations.
“Tool Retract” allows you to program

MILLPWR

to raise the tool at regular intervals.

Using the softkeys, select either

NUMBER OF CYCLES

or

DISTANCE

. Your selection will be

applied to all three features.

Advertising