PROGRAMMING

MILLPWR

®

Operation Manual

3-12

Finally, we'll set datum for the Z-axis:

Position the tool so that its tip touches the top surface of your
part.

Using the keypad, enter "0" into the "Z:" field (or press the
Z = 0 softkey).

Press the

ENTER

key.

Highlight the “Z Retract” field.

Either:

Enter the Z-axis retract position (the position that you want the quill to return to
between steps—it must be located above the top surface of your part); OR

Raise the quill to the desired position, then press the

TEACH

softkey.

Press the

USE

key.

Datum and the Z-axis retract position have now been established.

It's a good idea to test your datum set-
ting before you begin programming. To
confirm that your new datum is correct:

Raise the tool and move the table
until both the X- and Y-axes dis
plays read "0.0000."

Lower the tool until it touches your part.

Check the tool's position—the lower left corner of the part should be
positioned directly beneath the center point of the tool.

Now check the readout screen. If the Z-axis says "0.0000," then your
datum is accurate and you can begin programming. If a value other
than 0.0000 appears in the Z-axis display, repeat the procedure for
establishing datum.

You can quickly
move to datum
for X and Y by
pressing the
POS key. Check
that your go to
position is
0.0000 for both
X and Y, then
press the GO
key.