GE Industrial Solutions AF-600 FP High Power (460V_575V 150HP and above) User Manual

Page 112

Advertising
background image

6.

Remove the soft charge resistor by removing the two mounting screws.

130BX83.10

1

2

Illustration 7.1: 41/43 Soft Charge Resistor (3 of 3)

380–480V: Clear wire leads.

525–690V: Black wire leads.

1

Soft charge resistor

2

Mounting screws (Step 6)

Reassembly

1.

Clean the heatsink surface with a mild solvent or alcohol solution.

2.

Reassemble the remaining parts in reverse order of their removal. Tighten the T25 and 8 mm mounting screws to 2.3 Nm (20 in-lbs) and T30 and 10 mm
to 4 Nm (35 in-lbs).

AF-650 GP and AF-600 FP High Power Service Manual

111

7

Advertising