8 5x-Frame Sizes Disassembly and Assembly Instructions

8.1 Electrostatic Discharge (ESD)

Frequency converters contain dangerous voltages when connected to mains voltage. No disassembly should be attempted with power applied.
Remove power to the frequency converter and wait at least 40 minutes to let the frequency converter capacitors fully discharge. Only a
competent technician should carry out service.

ELECTROSTATIC DISCHARGE (ESD)
Many electronic components within the frequency converter are sensitive to static electricity. Voltages so low that they cannot be felt, seen or heard can reduce
the life, affect performance, or completely destroy sensitive electronic components.

Use proper electrostatic discharge (ESD) procedures to prevent damage to sensitive components when servicing the frequency converter.

NB!
Frame size is used throughout this manual where ever procedures or components differ between frequency converters based upon the unit's physical size.
Refer to the tables in the Introduction section to determine 5x-frame size definitions.

8.2 Instructions

8.2.1 Control Card and Control Card Mounting Plate

1.

Open the front panel door or remove the front cover, depending on the unit type.

2.

(See Illustration 8-1) Unplug the Keypad ribbon cable (not shown) from the control card or remove the Keypad, depending on the unit type. The
Keypad can be removed by hand.

3.

Remove the Keypad cradle. Keypad cradle can be removed by hand.

4.

Remove any customer control wiring from the control card terminal blocks.

5.

Remove the 4 screws (T20 Torx) securing the control card mounting plate to the control assembly support bracket.

6.

Unplug the ribbon cable from the back of the control card.

Reinstall in reverse order of this procedure. The red conductor on the ribbon cable between the control card and the power card should be on the bottom of the
connector. Tighten the control card mounting plate screws to 1 Nm (8 in-lb).