GE Industrial Solutions AF-600 FP High Power (460V_575V 150HP and above) User Manual

Page 52

Advertising
background image

No.

Description

Warning

Alarm/Trip

Alarm/Trip Lock

26

Brake resistor power limit

(X)

(X)

27

Brake chopper fault

X

X

28

Brake check failed

(X)

(X)

29

Heatsink temp

X

X

X

30

Motor phase U missing

(X)

(X)

(X)

31

Motor phase V missing

(X)

(X)

(X)

32

Motor phase W missing

(X)

(X)

(X)

33

Inrush fault

X

X

34

Network communication fault

X

X

36

Line failure

X

X

38

Internal fault

X

X

39

Heatsink sensor

X

X

40

Overload of Digital Output Terminal 27

(X)

41

Overload of Digital Output Terminal 29

(X)

42

Overload of Digital Output on X30/6 or Overload of Digital Output on X30/7

(X)

46

Power card supply

X

X

47

24 V supply low

X

X

X

48

1.8 V supply low

X

X

49

Speed limit

X

50

Auto Tune calibration failed

X

51

Auto Tune check U

nom

and I

nom

X

52

Auto Tune low I

nom

X

53

Auto Tune motor too big

X

54

Auto Tune motor too small

X

55

Auto Tune parameter out of range

X

56

Auto Tune interrupted by user

X

57

Auto Tune time-out

X

58

Auto Tune internal fault

X

X

59

Current limit

X

60

External interlock

X

61

Encoder loss

(X)

(X)

62

Output frequency at maximum limit

X

X

63

Mechanical brake low

(X)

64

Voltage limit

X

65

Control board overtemperature

X

X

X

66

Heatsink temperature low

X

67

Option module configuration has changed

X

68

Safe stop activated

(X)

(X)

1)

69

Power card temperature

X

X

70

Illegal Drive configuration

X

71

PTC 1 safe stop

X

X

72

Dangerous failure

X

X

X

73

Safe stop auto restart

X

79

Illegal PS config

X

X

80

Drive Restored to Factory Settings

X

81

CSIV corrupt

X

82

CSIV parameter error

X

90

Encoder loss

(X)

(X)

91

Analog input 54 wrong settings

X

92

No flow

(X)

(X)

93

Dry pump

(X)

(X)

94

End of curve

(X)

(X)

95

Broken belt

(X)

(X)

96

Start delayed

(X)

97

Stop delayed

(X)

98

Clock fault

X

200

Fire mode

(X)

201

Fire mode was active

(X)

202

Fire mode limits exceeded

(X)

243

Brake IGBT

X

X

244

Heatsink temperature

X

X

X

245

Heatsink sensor

X

X

246

Power card supply

X

X

247

Power card temperature

X

X

248

Illegal PS config

X

X

250

New spare part

X

251

New Model Number

X

X

Table 4.3: Alarm/warning code list