5. Disconnect the in-line Molex connector.
6. Remove the fan assy by removing the 6 (8 mm) retaining nuts from the stud. Note that the fan assembly weighs approximately 8 kg (18 lbs).
Reinstall in reverse order of this procedure. Tighten mounting nuts to 2.3 Nm (20 in-lbs).
130BX89.10
1
2
Illustration 7.1: Fan Assembly (2 of 2)
1
Inline Molex connector (Step 5)
2
Retaining nut (Step 6)