5. Disconnect the in-line Molex connector.

6. Remove the fan assy by removing the 6 (8 mm) retaining nuts from the stud. Note that the fan assembly weighs approximately 8 kg (18 lbs).

Reinstall in reverse order of this procedure. Tighten mounting nuts to 2.3 Nm (20 in-lbs).

130BX89.10

1

2

Illustration 7.1: Fan Assembly (2 of 2)

1

Inline Molex connector (Step 5)

2

Retaining nut (Step 6)