Output – GW Instek AFG-2000 User Manual User Manual

Page 110

Advertising
background image

AFG-2000 Series User Manual

108

0%

50%

100%

Note

For ramp waveforms, the Apply command and
AM/FM modulation modes ignore the current
symmetry settings.

Syntax

SOURce[1]:RAMP:SYMMetry {< percent>
|MINimum|MAXimum}

Example

SOUR[1]:RAMP:SYMM MAX

Sets the symmetry to the 100%.

Query Syntax

SOURce[1]:RAMP:SYMMetry?
{MINimum|MAXimum}

Return Parameter <NR3>

Returns the symmetry as a percentage.

Query Example

SOUR1:RAMP:SYMMetry?

>+1.0000E+02

The symmetry is set as 100%.

OUTPut

Set

Query

Description

Enables/Disables or queries the front panel
output. The default is set to off.

Syntax

OUTPut {OFF|ON}

Example

OUTP ON

Turns the output on.

Query Syntax

OUTPut?

Return Parameter 1

0

ON
OFF

Query Example

OUTP?

>1

The output is currently on.