Source[1]:am:depth – GW Instek AFG-2000 User Manual User Manual
Page 115
REMOTE INTERFACE
113
Parameter
<frequency>
2 mHz~ 20 kHz
Example
SOUR1:AM:INT:FREQ +1.0000E+02
Sets the modulating frequency to 100Hz.
Query Syntax
SOURce[1]:AM:INTernal:FREQuency?
[MINimum|MAXimum]
Return Parameter <NR3>
Returns the frequency in
Hz.
Query Example
SOUR1:AM:INT:FREQ? MIN
>+1.0000E+02
Returns the minimum frequency allowed.
SOURce[1]:AM:DEPTh
Set
Query
Description
Sets or queries the modulation depth for internal
sources only. The default is 100%.
Note
The function generator will not output more than
±5V, regardless of the modulation depth.
The modulation depth of an external source is
controlled using the ±5V MOD input port on the
rear panel, and not the SOURce[1]:AM:DEPTh
command.
Syntax
SOURce[1]:AM:DEPTh {<depth in percent>
|MINimum|MAXimum}
Parameter
<depth in percent>
0~120%
Example
SOUR1:AM:DEPT 50
Sets the modulation depth to 50%.
Query Syntax
SOURce[1]:AM:DEPTh? [MINimum|MAXimum]
Return Parameter <NR3>
Return the modulation depth as a
percentage.
Query Example
SOUR1:AM:DEPT?
>+1.0000E+02
The modulation depth is 100%.