Setting the modulation source – GW Instek AFG-2000 User Manual User Manual

Page 51

Advertising
background image

OPERATION

49

Example:
DEP= 100%

Note

When the modulation depth is greater than
100%, the output cannot exceed ±5VPeak
(50Ω load).
If an external modulation source is
selected, modulation depth is limited to
±5V from the MOD input port on the rear
panel. For example, if the modulation depth
is set to 100%, then the maximum
amplitude is +5V, and the minimum
amplitude is -5V.

Setting the Modulation Source

Panel Operation

1. Press the Shift + INT/EXT

key to select the
modulation source.

Shift

+

INT/EXT

kHz/Vrms

2. The modulation source will be displayed at

the bottom of the screen.

Note

If an external modulation source is selected,
modulation depth is limited to ± 5V from the
MOD input port on the rear panel. For example,
if the modulation depth is set to 100%, then the
maximum amplitude is +5V, and the minimum
amplitude is -5V.