Fm carrier waveform, Setting the carrier frequency – GW Instek AFG-2000 User Manual User Manual
Page 54
AFG-2000 Series User Manual
52
Example:
FM activated
Note
FM modulation can be deactivated by pressing the FM
key again.
FM Carrier Waveform
Background
The FUNC key selects the FM carrier waveform.
Sine, square or ramp waveforms can be used as the
carrier. The default waveform is set to sine. Noise
is not available as a carrier shape. Before the
carrier shape can be selected, ensure FM is active,
page 51.
Selecting the
Carrier Shape
1. Press the FUNC key
repeatedly to select a
carrier waveform (Sine,
Square, Ramp).
FUNC
→
Range
FM Carrier Shape sine, square, ramp
Setting the Carrier Frequency
Background
When using the AFG-2100 function generator, the
carrier frequency must be equal to or greater than
the frequency deviation.
Panel Operation
1. Press FREQ key.
FREQ