AFG-2000 Series User Manual

118

Syntax

SOURce[1]:FM:DEViation {<peak deviation in
Hz>|MINimum|MAXimum}

Parameter

<peak deviation in Hz>

DC ~ 25MHz*
DC~1MHz (Ramp)

*Limited to 12MHz for AFG-2112, 5MHz for
AFG-2105.

Example

SOUR1:FM:DEV MAX

Sets the frequency deviation to the maximum
value allowed.

Query Syntax

SOURce[1]:FM:DEViation? [MINimum|MAXimum]

Return Parameter <NR3>

Returns the frequency
deviation in Hz.

Query Example

SOURce1:FM:DEViation? MAX
>+1.0000E+06

The maximum frequency deviation for the current
function is 1MHz.