124

SOURce[1]:SWEep:STATe

Set

Query

Description

Sets or disables Sweep mode. By default sweep is
disabled. Sweep must be enabled before setting
other parameters.

Note

Any modes will be disabled if sweep mode is
enabled.

Syntax

SOURce[1]:SWEep:STATe {OFF|ON}

Example

SOUR1:SWE:STAT ON

Enables sweep mode.

Query Syntax

SOURce[1]:SWEep:STATe?

Return Parameter 0

Disabled (OFF)

1

Enabled (ON)

Query Example

SOUR1:SWE:STAT?
>1

Sweep mode is currently enabled.

SOURce[1]:FREQuency:STARt

Set

Query

Description

Sets the start frequency of the sweep. 100Hz is the
default start frequency.

Note

To sweep up set the stop frequency higher than the
start frequency. Set the stop frequency lower than
the start frequency to sweep down.

Syntax

SOURce[1]:FREQuency:STARt
{<frequency>|MINimum|MAXimum}

Parameter

<frequency> 0.1Hz ~ 25MHz*

0.1Hz ~ 1MHz (Ramp)

*AFG-2112 limited to 12MHz, AFG-2105 limited to
5MHz.