In-Situ Aqua TROLL 400 Modbus and SDI-12 Reference Guide User Manual

Page 50

Advertising
background image

Register

Size

(registers)

Mode & Access Level

(R/W)

Data

Type

Description

1521

1

R1/W3

16 bits Alarm and warning enable bits

(default = 0)

Bit 0 = High alarm enabled

Bit 1 = High warning enabled

Bit 2 = Low warning enabled

Bit 3 = Low alarm enabled

Bit 4 = Sensor calibration warning

1522

2

R1/W3

float

High alarm set value

(default = 0.0)

1524

2

R1/W3

float

High alarm clear value

(default = 0.0)

1526

2

R1/W3

float

High warning set value

(default = 0.0)

1528

2

R1/W3

float

High warning clear value

(default = 0.0)

1530

2

R1/W3

float

Low warning clear value

(default = 0.0)

1532

2

R1/W3

float

Low warning set value

(default = 0.0)

1534

2

R1/W3

float

Low alarm clear value

(default = 0.0)

1536

2

R1/W3

float

Low alarm set value

(default = 0.0)