VerifyNow System User Manual |

USA

Term

Description

Adenosine

diphosphate

ADP. When secreted by activated platelets from storage granules, ADP activates

additional platelets in circulation through two G protein-coupled P2 receptors,

P2Y1 and P2Y12.

Anti-platelet

Platelet inhibition may be induced in response to an anti-platelet agent. Three

classes of potent anti-platelet agents include acetylsalicylic acid (aspirin), P2Y12

inhibitors, and glycoprotein (GP) IIb/IIIa inhibitors.

Arachidonic acid

In an activated platelet, arachidonic acid is converted by cyclo-oxygenase (COX-1)

to prostaglandin G

2

(PGG

2

) and PGH

2

and then to thromboxane A2. Aspirin affects

platelet function by irreversibly inhibiting the cyclo-oxygenase (COX) activity of

prostaglandin (PG) H-synthase, which in turn blocks the metabolism of arachidonic

acid to thromboxane A2 (TXA2).

Aspirin

Acetylsalicylic acid. The primary pharmacological effect of aspirin on platelets is to

decrease the activation of the GP IIb/IIIa receptor and activation of other platelets.

Aspirin reaction

units

Results for the Aspirin test are interpreted based on the extent of platelet

aggregation measured and reported in Aspirin Reaction Units (ARU).

Aggregation,

platelets

The binding of the activated platelet IIb/IIIa receptors to fibrinogen (and vWF)

results in the formation of platelet-platelet and platelet-matrix adhesive interactions

and the formation of a stable, larger platelet aggregate at the site of injury.

Alarm

A type of message that displays after an unexpected event. Alarms are likely

system problems, and in general not serviceable by the customer.

ARU

See Aspirin Reaction Units

Test device

There are three types of test devices relating to the appropriate platelet

function test: Aspirin, P2Y12, and GP IIb/IIIa inhibitors (specifically abciximab or

eptifibatide). Each single-use, test device consists of a sample well, staging well,

and four detection wells

Test device port

The test device port holds a VerifyNow test device during the test.

Attention

A type of message that displays after an unexpected event. These events may be

simple issues that can be easily addressed by the customer.

Bar code

A series of vertical black and white lines on the white test device package (pouch).

The label stores information about the test type, lot code, expiration, device

calibration factors.

Bar code

Scanner

The bar code scanner scans a bar code on the white test device package, decodes

the bar code, and passes the information to the instrument software.

Baseline

A sample can be drawn prior to drug administration, and it can be used as a

baseline reading for determining percent inhibition (for IIb/IIIa test).

Cleaning device

A single use, disposable plastic component with an adhesive strip. The cleaning

device is used to remove debris from a pneumatic port connection inside the test

device port.

Clopidogrel

Clopidogrel (trade name Plavix

®

- clopidogrel bisulfate) is a potent oral antiplatelet

agent used in the treatment of coronary artery disease, peripheral vascular

disease, and cerebrovascular disease. As a thienopyridine, its mechanism of

action is inhibition of the P2Y12 receptor.

Cover

A plastic door on the instrument that shields the test device port from ambient light.

Date extension

When Accumetrics issues a date extension notification for a specific lot of test

devices, these devices can be used after the original expiration date.